62
Read number of items currently stored in Preset 2 Returned packet indicates 4 items available to
read
F 84 01 42 00 F4 - BB CR F 44 01 42 00 F4 00002 FC CR
Read the Function for the first item in the preset /
macro
Payload is the Function stored 86 = Zoom
F 84 01 42 00 F3 - BA CR F 44 01 42 00 F3 000086 ?80 CR
Read the Data for the first item in the preset / macro Payload is the data for the function – 100%
F 84 01 42 00 F2 - B9 CR F 44 01 42 00 F2 000064 5D CR
Read the Function for the second item in the preset /
macro
Payload is the Function stored 87 = Shrink
F 84 01 42 00 F3 - BA CR F 44 01 42 00 F3 000087 81 CR
Read the Data for the second item in the preset /
macro
Payload is the data for the function – 100%
F 84 01 42 00 F2 - B9 CR F 44 01 42 00 F2 000064 5D CR
The above example shows the read for all the items within macro 0. The first
command reads the number of items available in the macro and resets the read
address. Then the following items read the function and then the data for each of
the items in the preset/macro. Following a read of the data for a macro internally
the next item in the macro is selected for reading so it is not possible to read the
same item twice without first re-reading the number of items in the macro.
10.5.2 Writing to a macro
In order to read a preset / macro the following commands must be sent in this
specific order – no other commands should be sent between these messages.
Packet sent Packet returned
SOP CMD CHA WIN OUT FUN PAY CS EOP SOP CMD CHA WIN OUT FUN PAY CS EOP
Clear macro
F 04 02 42 00 F1 000001 3A CR F 44 02 42 00 F1 000001 7A CR
Write the function for first item in macro 3 = Zoom
F 04 02 42 00 F3 000086 C1 CR F 44 02 42 00 F3 000011 01 CR
Write data for the first item = 100
F 04 02 42 00 F2 000064 9E CR F 44 02 42 00 F2 000011 DE CR
Write the function for the second = shrink
F 04 02 42 00 F3 000087 C2 CR F 44 02 42 00 F2 000011 02 CR
Write the data for the second item = 100
F 04 02 42 00 F2 000064 9E CR F 44 02 42 00 F3 000011 DE CR
10.5.3 Run and Restore macros
Macros once programmed can be run by sending one of the following commands.
By running macro 5 the unit can be restored to its previously saved state, when
used in conjunction with the other macros this allows a default setup or baseline for
the unit to be created.
Packet sent Packet returned